Hach® HQD Laboratory Meters
Designed for water quality experts, the advanced Hach HQD laboratory meters take the guesswork out of measurements. All HQD meters feature an advanced yet simple user interface that does not require manuals or training to operate. HQD meters connect with smart Intellical electrodes and automatically recognize the testing parameter, calibration history, and method settings to minimize errors and setup time.
A wide variety of Intellical laboratory electrodes are available to meet the most demanding laboratory applications. Intellical Red Rod pH electrodes offer exceptional performance and response time across a wide variety of sample types. The LBOD probe utilises optical technology to provide fast, accurate Dissolved Oxygen measurements while dramatically reducing maintenance costs. Additional probes for Conductivity, Total Dissolved Solids (TDS), Ammonia, Ammonium, Fluoride, Nitrate, Sodium, and RedOx (ORP) measurements complete the Intellical portfolio.
Choose from 3 models, including the dual-input HQ440D and single-input HQ430D versions. These multi-parameter meters offer the ultimate in versatility and redundancy - perfect for budget-constrained laboratories.
Item ID | Model | Includes | DO Range | Parameter | TDS Range | DO Resolution | pH Resolution | Salinity Range | TDS Resolution | Price | Packaging |
---|---|---|---|---|---|---|---|---|---|---|---|
HACH 8505350 | |||||||||||
HACH 8505350 |
HQ440D – Multi/2 Channels | Meter, Electrode Stand w/electrode holder, combo refillable glass pH electrode w/cable, pH Buffer Kit, pH electrode storage soln, pH Electrode cleaning soln, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Operating Documentation | 0.1 to 20.0 mg/L, 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8505450 | |||||||||||
HACH 8505450 |
HQ440D – Multi/2 Channels | Meter, Electrode Stand w/electrode holder, RedRod combo refillable glass pH electrode w/cable, pH Buffer Kit, pH electrode storage soln, pH Electrode cleaning soln, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Documentation. | 0.1 to 20.0 mg/L, 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L up to 0.1 g/L Upon Measuring Range |
|
|
HACH 8505850 | |||||||||||
HACH 8505850 |
HQ440D – Multi/2 Channels | Meter, Electrode Stand w/electrode holder, combined refillable glass pH electrode w/ cable, pH Buffer Kit, pH electrode storage soln, pH Electrode cleaning soln, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Documentation | 0.1 to 20.0 mg/L, 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L up to 0.1 g/L Upon Measuring Range |
|
|
HACH 8506050 | |||||||||||
HACH 8506050 |
HQ440D – Multi/2 Channels | Meter, Electrode Stand w/electrode holder, RedRod combo refillable glass pH electrode w/cable, pH Buffer Kit, pH electrode storage soln, pH Electrode cleaning soln, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Operating Documentation | 0.1 to 20.0 mg/L, 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L up to 0.1 g/L Upon Measuring Range |
|
|
HACH 8506250 | |||||||||||
HACH 8506250 |
HQ440D – Multi/2 Channels | Meter, Electrode Stand w/electrode holder, Combined puncture pH electrode for Semi-Solid Samples w/cable, pH Buffer Kit, pH Electrode cleaning soln, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Operating Documentation | 0.1 to 20.0 mg/L, 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L up to 0.1 g/L Upon Measuring Range |
|
|
HACH 8506450 | |||||||||||
HACH 8506450 |
HQ440D – Multi/2 Channels | Meter, Electrode Stand w/electrode holder, Combined RedRod high-alkalinity pH Electrode w/cable, pH Buffer Kit, pH electrode storage soln, pH Electrode cleaning soln, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Operating Documentation | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8507450 | |||||||||||
HACH 8507450 |
HQ440D – Multi/2 Channels | Universal electrode Stand, PHC729 Combined RedRod pH Electrode, pH Buffer Kit, pH electrode storage solution, pH Electrode cleaning solution, 4 Alkaline 1,5V AA batteries, Power Supply Adapter, Power Cord, USB cable, and Operating Documentation. | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable between 0.001 to 0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8507600 | |||||||||||
HACH 8507600 |
HQ440D – Multi/2 Channels | Meter, Electrode Stand w/holder, Ammonia Ion Selectve Electrode w/cable, Nitrogen Amm std solns: 1mg/L, 10mg/L & 100mg/L. Amm ISAB powder pillows, Ammonia electrode storage soln, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Documentation | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8507800 | |||||||||||
HACH 8507800 |
HQ440D – Multi/2 Channels | Meter, Electrode Stand w/holder, Amm Ion Selective Electrode w/cable, Nitrogen Amm std solutions: 1mg/L, 10mg/L & 100mg/L. Amm ISAB powder pillows, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Documentation | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), and Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8507900 | |||||||||||
HACH 8507900 |
HQ440D – Multi/2 Channels | Meter, Electrode Stand w/electrode holder, Chloride Ion Selective Electrode w/cable, Chloride std solns: 0,00282N, 1000mg/L, 12,5g/L Voluette Ampules Chloride (NIST). Chloride ISAB powder pillows, 4 batteries, Power Supply Adapter, Power Cord, USB cable | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), and Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8508000 | |||||||||||
HACH 8508000 |
HQ440D – Multi/2 Channels | Meter, Electrode Stand w/electrode holder, Fluoride Ion Selective Electrode w/cable, Fluoride std solns: 0,5mg/L, 1mg/L, 10mg/L. Fluoride ISAB powder pillows, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Documentation | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), and Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8508500 | |||||||||||
HACH 8508500 |
HQ440D – Multi/2 Channels | Multi Meter, Luminescent/Optical DO (LDO) electrode for BOD Measurement w/1m cable, 300mL BOD Bottle (100ea) Bottle Stoppers (25ea) BOD Bottle cap (6ea) 4 batteries, Power Supply Adapter, Power Cord, USB cable and Operating Documentation | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), and Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8508600 | |||||||||||
HACH 8508600 |
HQ440D – Multi/2 Channels | Meter, Universal electrode Stand w/electrode holder, pH Ultra Refillable pH Electrode w/cable, pH Buffer Kit, pH electrode storage soln, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Operating Documentation | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8508700 | |||||||||||
HACH 8508700 |
HQ440D – Multi/2 Channels | Meter, Stand w/electrode holder, pH Ultra Refill pH Electrode w/cable, Buffer Kit, electrode storage soln, conduct/TDS/salinity cell w/cable, NaCl cond std, (LDO) electrode w/cable, BOD Bottle w/stopper, 4 batt., Pwr Supp Adapt, Power Cord, USB cable | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), and Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8509600 | |||||||||||
HACH 8509600 |
HQ430D – Multi/1 Channel | Meter, Electrode Stand w/electrode holder, conductivity/TDS/salinity cell w/cable, NaCl conductivity std (100 µS/cm, 491mg/L, 100mL), 4 batteries, Power Supply Adapter, Power Cord, USB cable and Documentation | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), and Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8510100 | |||||||||||
HACH 8510100 |
HQ440D – Multi/2 Channels | Meter, Stand w/holder, Std Rfl pH Electrode w/cable, Buffer Kit, storage soln, Luminescent/Optical DO (LDO) electrode w/cable, Disposable BOD Bottles, Bottle Stoppers, Bottle caps, 4 batteries, Power Supply Adapter, Power Cord, USB cable and Documentation | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), and Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH 8510200 | |||||||||||
HACH 8510200 |
HQ440D – Multi/2 Channels | Meter, Univ electrode Stand w/holder, pH Ultra Refillable pH Electrode w/cable, Buffer Kit, pH electrode storage soln cond/TDS/salinity cell w/cable, NaCl cond std (1000µS/cm, 491mg/L), 4 batteries, Power Adapter, Power Cord, USB cable and Documentation | 0.1 to 20.0 mg/L, 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L up to 0.1 g/L Upon Measuring Range |
|
|
HACH HQ411D | |||||||||||
HACH HQ411D |
HQ411D – pH/1 Channel | HQ411D Meter, Basic User Manual, Documentation CD, Quick Reference Guide, 4 AA Batteries | - | pH/Oxydo Reduction Potential (ORP) | - | - | Selectable: 0.001/0.01/0.1 pH | - | - |
|
|
HACH HQ430D | |||||||||||
HACH HQ430D |
HQ430D – Multi/1 Channel | Meter, 4 AA batteries, universal power adapter, USB cable for data transfer, quick start guide and user manual | 0.1 to 20.0 mg/L, 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|
HACH HQ440D | |||||||||||
HACH HQ440D |
HQ440D – Multi/2 Channels | Meter, 4 AA batteries, universal power adapter, USB cable for data transfer, quick start guide and user manual | 0.1 to 20.0 mg/L, 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L up to 0.1 g/L Upon Measuring Range |
|
|
HACH HQDBODMGR | |||||||||||
HACH HQDBODMGR |
HQ440D – Multi/2 Channels | HQ440D Laboratory Multi Meter, LBOD101 Luminescent/Optical Dissolved Oxygen (LDO) electrode for BOD Measurement with 1 m cable, 4 Alkaline 1,5V AA batteries, Power Supply Adapter, Power Cord, USB cable for data transfer, and Operating Documentation. | 0.1 to 20.0 mg/L (ppm), 1 to 200% Saturation | pH/Oxydo Reduction Potential (ORP), Conductivity/Total Dissolved Solid (TDS)/Salinity/Resistivity, Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), and Ion Selective Electrode (ISE): Ammonia, Ammonium, Chloride, Fluoride, Nitrate, Sodium | 0.00 mg/L to 50.0 g/L as NaCl | 0.1 | Selectable: 0.001/0.01/0.1 pH | 0 to 42 (ppt) (‰) | 0.01 mg/L to 0.1 g/L Depending Upon Measuring Range |
|
|