HACH LXV445.99.22112

Hach Chemical
TU5300sc Low Range Laser Turbidimeter with Flow Sensor and RFID, EPA Version


Turbidity Range:
 
0 to 700 NTU / FNU / TE/F / FTU, and 0 to 175 EBC
Model:
 
TU5300sc
Certifications/Compliance:
 
CE Compliant
Cable Length:
 
1.6m
Calibration:
 
For Formazin and Stablcal®: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range
Warranty:
 
24 Months
Hach Chemical® TU5300sc Low Range Laser Turbidimeter with Flow Sensor and RFID, EPA Version

Compliant with EPA approved Hach Method 10258 and perfect for conventional filtration and other low range turbidity measurements, the TU5300sc employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability between measurements. For the first time you will be able to remove uncertainty of which measurement to trust between your lab and process instruments, thanks to identical 360° x 90° Detection Technology in any TU5 Series turbidimeter.

The TU5300sc Low Range Laser Turbidimeter dramatically reduces the time needed to get a turbidity measurement you can rely on. With a 10mL sample size, response time is over 15 times faster than a 1720E. A stable laser light source eliminates the need for annual lamp replacements. The turbidimeter’s measurement surface area has been reduced by 98%, allowing you to save time cleaning. With a mounting pattern identical to the 1720E, replacing your previous turbidimeter is fast and simple.

All of this, along with the ability to measure to 0.002 NTU, gives you the next standard in the evolution of turbidity.

A flow meter is included with this turbidimeter that continuously measures flow through the instrument and displays the flow value on screen. Current flow can be output to SCADA via 4-20mA or digital communications.

RFID technology included with this turbidimeter delivers easy calibration and simple, paperless turbidity measurement comparisons between your process turbidimeter and the TU5200.

  • Groundbreaking 360° x 90° Detection™ Technology
  • Matching lab and online results
  • Everything about turbidity – faster
  • No surprises

Hach Chemical
Turbidity Range:
 
0 to 700 NTU / FNU / TE/F / FTU, and 0 to 175 EBC
Model:
 
TU5300sc
Certifications/Compliance:
 
CE Compliant
Cable Length:
 
1.6m
Calibration:
 
For Formazin and Stablcal®: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range
Warranty:
 
24 Months
Accuracy:
 
±2% or 0.01 NTU from 0 to 40 NTU; ±10% of reading from 40 to 1000 NTU based on Formazin primary standard
Turbidity Resolution:
 
0.0001 NTU / FNU / TE/F / FTU / EBC
Includes:
 
TU5300sc Turbidimeter, User Manual, Wall Mount, Vial Replacement Tool, Screw Set, Drying Cartridge, Flow Regulator, Service Bracket, Flow Sensor
Lighting Type:
 
Class 2 Laser Product, with Embedded 650nm (EPA 0.43 mW) or Class 1 Laser Product, with Embedded 850nm (ISO)
Operating Temperature:
 
0 to 50°C